Vehicle Loop Detector for Gate Barrier
Model No.: PD-132
- PD-132 Inductive Vehicle Single Loop Detector
- for Automatic Gate opener barrier gate Traffic Inductive Vehicle access
- Leave a message to us, if you need DC12V/DC24V/AC110V,no message send AC220V
Install Detector:
- The detector must be installed in a convenient weatherproof location as close to the loop as possible.
- Installation location must choose to stay away from the heat source,
- it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet).
- A correct loop configuration and detector installation will ensure a successful inductive loop detection system.
- Loop of several important parameters include
- loop figure, size, and turns, install methods (details as “Loop installation guide”).
Supply voltage | 230V AC, 115V AC, 24V DC/AC, 12V DC/AC (See the label on the detector) |
Voltage tolerance AC | +10%/-15% |
Voltage tolerance DC | ±15% |
Power Consumption | 4.5VA |
Output relays | 240V/5A |
Operating temperature | -20℃ ~ 65℃ |
Storage temperature | -40℃ ~ 85℃ |
Frequency range | 20 KHz ~ 170 KHz |
Reaction time | 10ms |
Signal holding time | Unlimited / limited when loop is permanently covered 10 minutes |
Sensitivity | Adjustable in 4 increments |
Loop inductance | Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH |
Loop connection wiring | Maximum length 20 meters, twisted at least 20 times per meter |
Size of Housing | L78 x W40 x H108mm |
Vehicle Loop Detector
- Product Code: Vehicle Loop Detector
- Availability: In Stock