PD-132 Vehicle Loop Detector for Gate Barrier
- Vehicle Loop Detector for gate
- Model No : PD-132
- PD-132 Inductive Vehicle Single Loop Detector
- for Automatic Gate opener barrier gate Traffic Inductive Vehicle access
- The detector must be installed in a convenient weatherproof location as close to the loop as possible.
- Installation location must choose to stay away from the heat source,
- it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet).
- A correct loop configuration and detector installation
- will ensure a successful inductive loop detection system.
- Loop of several important parameters include: loop figure, size,
- and turns, install methods (details as Loop installation guide ).
Specifications:
- Supply voltage : 12V DC
- Operating temperature : -20℃ ~ 65℃
- Storage temperature : -40℃ ~ 85℃
- Frequency range : 20 KHz ~ 170 KHz
- Reaction time : 10ms
- Signal holding time : Unlimited / limited when loop is permanently covered 10 minutes
- Sensitivity : Adjustable in 4 increments
- Loop inductance : Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH
- Loop connection wiring : Maximum length 20 meters, twisted at least 20 times per meter
- Size of Housing : L78 x W40 x H108mm
PD-132 Loop Detector 12V
- Brand: EUROMATIC
- Product Code: PD-132 Loop Detector 12V
- Availability: In Stock
-
180 AED
Related Products
PD-232 Loop Detector
PD-232 Vehicle Loop Detector for Gate BarrierVehicle Loop Detector for gateModel No : PD-232PD-232 Inductive Vehicle Single Loop Detectorfor Automatic Gate opener barrier gate Traffic Inductive Vehicle accessThe detector must be installed in a convenient weatherproof location as close to the loop as possible.Installation location must choose to stay away from the heat source,it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet).A correct loop configuration and detector installationwill ensure a successful inductive loop detection system.Loop of several important parameters include: loop figure, size,and turns, install methods (details as Loop installation guide ).Specifications:Supply voltage : 230V ACLoop Quantity : 2Sensitivity : adjustable in 4 increments (high .medium high. medium, low)Operating temperature : -20°C ~ 70°CStorage temperature : -40°C ~ 85°CFrequency range : 20KHz ~ 170KHzReaction time : 100msLoop inductance : Ideal:80μH ..
199 AED
PD-132 Loop Detector 24V
PD-132 Vehicle Loop Detector for Gate BarrierVehicle Loop Detector for gateModel No : PD-132PD-132 Inductive Vehicle Single Loop Detectorfor Automatic Gate opener barrier gate Traffic Inductive Vehicle accessThe detector must be installed in a convenient weatherproof location as close to the loop as possible.Installation location must choose to stay away from the heat source,it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet).A correct loop configuration and detector installationwill ensure a successful inductive loop detection system.Loop of several important parameters include: loop figure, size,and turns, install methods (details as Loop installation guide ).Specifications:Supply voltage : 24V DCOperating temperature : -20℃ ~ 65℃Storage temperature : -40℃ ~ 85℃Frequency range : 20 KHz ~ 170 KHzReaction time : 10msSignal holding time : Unlimited / limited when loop is permanently covered 10 minutesSensitivity : Adjustable in 4 incremen..
190 AED
Loop Cable for Vehicle Loop Detector
Loop Cable for Vehicle Loop DetectorHigh temperature and aging resistanceCorrosion and acid and alkali resistanceThe groove width is generally 3-5mm40-50mm depthLoop Cable for Vehicle Loop DetectorWhat is loop detector cable?Used in vehicle monitoring equipment for detection of traffic movements via creation of inductive loop to frequency signal flowing in cable and metallic parts of vehicle. These cables are designed for installation in a slot cut into the carriageway.How do you install a loop detector wire?Cutting a slot.Cleaning and drying the slot.Laying in the inductive-loop detector wire.Sealing the sawcut.Connecting the wire to the lead-in cable.Connecting the cable to the terminal strip in the cabinet.Ensuring the harness connects the terminal strip to the electronics unit.Specifications:color : redMaterial : tinned copper wireBelow 3 meters : Ensure that the inductance value is between 100uH and 30OuH3-6 meters : 5-6 turns6-10 meters : 4-5 turns10-25 meters : 3 ..
199 AED